7 min read
BeeHeat split heat pump

New powerful and efficient heat pump at an attractive price. The outdoor unit is extremely compact even for the capacity size of 16,2 kW.   

The picture shows a family around the kitchen table, with a Mycond BeeHeat split series Mycond heat pump indoor unit hanging on the wall . Mum, dad and two children are happy because the heat pump is heating their home.

Compactness and efficiency - this is what modern heating technology looks like today.  Mycond BeeHeat is a split system: the heat pump consists of outdoor and indoor units.
The outdoor unit with a capacity of 16.2 kW (A7/W35) has extremely compact dimensions, which significantly simplifies installation.

Compatible with existing heating systems 

When upgrading the heating system, a heat pump can be added as an additional heat source. In this case, the existing boiler operates only at particularly low outdoor temperatures, while the heat pump operates for the entire heating season. Such a heating system is more reliable and economical to operate.

Outdoor unit 

  • Heating capacity 6,0/ 7,9 / 9,7 / 12,1 / 14,3 / 16,2kW (A7/W35)
  • Heating operation at outdoor temperature down to -25 °C
  • Cooling capacity  6,0/ 7,7 / 9,6 / 10,9 / 12,7 / 14,0kW (A35/W7)
  • Adjustable capacity thanks to the inverter compressor
  • Power saving variable speed fan
  • Low noise level of the outdoor unit
  • Coated evaporator with corrugated fins for higher efficiency
  • 4-way diverter valve
  • Electronic expansion valve (EEV)
  • Refrigerant R32
  • Ribbon heater, as frost protection for the outdoor unit condensate pan
The image shows the interior of the MYCOND BeeHeat split heat pump outdoor unit.


Indoor unit 

  • Compact installation
  • Integrated heat exchanger (condenser) with frost protection
  • Integrated high efficiency circulation pump
  • Integrated electric heater
  • Integrated safety valve
  • Integrated pressure sensor
  • Integrated flow rate monitoring
  • Integrated expansion vessel 5l
  • Simple and easy-to-operate heat pump controlle
The image shows the internal filling of the MYCOND BeeHeat split heat pump indoor unit.


Remote control from smartphone

Heat pumps use many solutions to ensure maximum user comfort.

The Mobile App allows you to very easily control the heat pump and the entire system from your smartphone: 

  • change the heating/cooling mode
  • change the set temperature
  • set a work schedule
  • receive error messages

Remote control allows you to constantly view the operation of the device on your smartphone.

The image shows a smartphone showing the mobile app that controls the heat pump via wi-fi.


Main Functions:

Heating Curve Function Using Heating Curve Logic,  users can set up the system to meet their optimum comfort levels based on the changing heat demand, insulation levels, etc.

Heat pump can adjust the outlet water temperatures based on the ambient temperature, by continually monitoring and adjusting it in opposite directions with the current ambient temperature levels to ensure the optimum in the living spaces.

The image shows a graph of the temperature change inside the house, depending on the outside temperature.


Room Temperature Control FunctioIn addition to the water temperature control function, users can also choose to control  the heating water temperatures, by setting it on their controller pads based on the room temperature.

In this mode heat pump will manage the outlet water temperature and work towards achieving and maintaining the set room temperature.

The picture shows a beautiful room with white walls and a gorgeous brown sofa and coffee table.



Auto Heat/Cool Switch-over Mode

BeeHeat has Automatic Heat/Cool Switch-over function to enable the user a truly unattended automatic operation of the system.

The picture shows a smartphone and two outlines of houses. The arrows from the smartphone show that it controls the climate in these houses.


Sleep Mode

In this mode BeeHeat heat pump adjust outlet water temperature or room temperature  to save energy and lowers the operation noise by reducing the working speed of the compressor and fan motor for optimum sleeping comfort.

The image shows a sleeping baby in bed.


Economical Operation

As the ambient temperature drops, the heating efficiency of heat pumps drops along. In some countries or regions, when ambient temperature drops to a certain level, usage of other heating sources,  like a gas boiler, may become more economical than the use of the heat pump.

BeeHeat unit allows the user to stop running the heat pump and turn on other heating sources, when the ambient temperature drops to a certain level.

The image shows the indoor and outdoor units of the MYCOND BeeHeat split heat pump.



SpecificationsUnitsMHS-N6BH
MHS-U6BH
MHS-N8BH
MHS-U8BH
MHS-N10BH
MHS-U10BH
MHS-N12BH
MHS-U12BH
MHS-N14BH
MHS-U14BH
MHS-N16BH
MHS-U16BH
Heating capacity (А7/W35)Coefficient of performance COP (А7/W35)kW 6,04,897.94,519,74,6212,14,5114,34,6116,24,41
Heating capacity min/max (А7/W35)kW2,8-7,13,4-8,93,6-10,25,6-14,05,9-15,06,5-16,5
Maximum heating capacity (А-7/W35)kW4,96,88,310,312,313,5
Coefficient of performance COP (А-7/W35) 2,943,053,12,72,72,6
Maximum cooling capacity (A35/W7)kW6,07,79,610,912,714,0
Energy efficiency ratio EER (A35/W7) 2,942,782,942,662,552,45
Operating ambient temperature (heating)°C-25…+43-25…+43-25…+43-25…+43-25…+43-25…+43
Operating ambient temperature (cooling)°C+8…+43+8…+43+8…+43+8…+43+8…+43+8…+43
Maximum flow temperature°C+60+60+60+60+60+60
Refrigerant type R32R32R32R32R32R32
Power supplyV / Hz230/50230/50230/50400/50400/50400/50
Sound power level (indoor/outdoor unit)dB(A)42/5842/5942/6042/6442/6542/68
Energy Efficiency Class       
– low temperature application (W35) A+++A+++A+++A+++A+++A+++
– medium temperature application (W55) A++A++A++A++A++A++

 

Dimensions

Indoor unit dimensions, refrigerant & water piping connections MHS-N6BH, MHS-N8BH, MHS-N10BH, MHS-N12BH, MHS-N14BH, MHS-N16BH 

The image shows a drawing with the overall dimensions of the Mycond heat pump of the BeeHeat split series.


Dimensions

Appearance and dimensions of MHS-U6BH, MHS-U8BH outdoor unit

The image shows a drawing with the overall dimensions of the Mycond heat pump of the BeeHeat split series.


Dimensions

Appearance and dimensions of MHS-U10BH і MHS-U12BH outdoor unit

The image shows a drawing with the overall dimensions of the Mycond heat pump of the BeeHeat split series.


Размеры

Appearance and dimensions of MHS-U14BH і MHS-U16BH outdoor unit


The image shows a drawing with the overall dimensions of the Mycond heat pump of the BeeHeat split series.
The image shows how to connect the MYCOND BeeHeat split heat pump to the heating system (radiators, floor heating system) and the hot water system.
The image shows how to connect the MYCOND BeeHeat split heat pump to the heating system (radiators, floor heating system) and the hot water system.


Comments
* The email will not be published on the website.